The types of fire extinguishers


2nd July 2019 by Eve Johnson

In this article

  • Fire classification

  • Water extinguishers

  • Foam extinguishers

  • CO2 extinguishers

  • Dry Powder extinguishers

  • Wet Chemical Extinguishers


Fire classification Fires can be placed into different classes depending on what material is burning. This classification then gives us information on the type of fire extinguisher we should use to put out the flames. Not all fires require the same type of extinguisher and the correct type has to be used for each blaze. Class A Class A fires are burning flammable solids as fuel. Examples of these include paper and wood. Extinguishers that can be used: Water, Foam, ABC Dry powder, Wet chemical Class B Class B fires are burning flammable liquids. Examples include petrol and paint. Extinguishers that can be used: Foam, CO2 Gas, ABC Dry powder Class C Class C fires burn flammable gases. A couple of examples are propane and butane. Extinguishers that can be used: ABC Dry powder Class D Class D fires are burning flammable metals. These may include lithium or magnesium. Extinguishers that can be used: Dry Special Powder Electrical Any fire involving electrical equipment is classed as an electrical fire. Extinguishers that can be used: CO2 Gas, ABC Dry powder Class F Class F fires are burning cooking oils or fat. Extinguishers that can be used: Wet chemical Which fire extinguisher should I use? Try our quiz.


Fire Safety Awareness CourseStudy online and gain a full CPD certificate posted out to you the very next working day. Learn more


Water extinguishers Water extinguishers are very common and should be used on solid materials only. This can include paper, wood or any other solid fuel. Water based extinguishers are essentially filled with water and use compressed air to help this come out. Some will also have an additive that will help make them more effective. They work to cool the fire, removing heat from the fire triangle and will effectively stop any fire that has started.

Can be used on:

  • Solid fuel fires

Not to be used on:

  • Solid fuel fires

  • Flammable liquids

  • Flammable gases

  • Flammable metal

  • Electrical fires

  • Cooking oil fires

Water extinguishers use a red label Foam extinguishers Foam extinguishers are used on burning liquids such as petrol or diesel fires. They can also be used on solid fuel fires in the same way as water extinguishers. Foam fire extinguishers are actually water based (this is why they can be used on solid fuels) and have a cooling effect. They also contain ‘Aqueous Film Forming Foam’ which smothers the fire and seals in any flammable vapours. This will prevent the fire from reigniting and is why they are used to treat flammable liquids. Since fire only burns on top of flammable liquids, a foam extinguisher will create a barrier that smothers the flames. Can be used on:

  • Solid fuel fires

  • Flammable liquids

Not to be used on:

  • Flammable gases

  • Flammable metal

  • Electrical fires

  • Cooking oil fires

Foam extinguishers use a cream label


CO2 extinguishers CO2 extinguishers are typically used on electrical equipment. They can also be used to extinguish flammable liquids in the same way as foam extinguishers. Since CO2 extinguishers are perfect for electrical fires, they are commonly found in offices or places where there is a lot of electrical devices. They work to replace the oxygen in the air with CO2 and will smother the fire in order to put it out. CO2 extinguishers are safe to be used on both high and low voltage electrical. Can be used on:

  • Flammable liquids

  • Electrical fires

Not to be used on:

  • Solid fuel fires

  • Flammable gases

  • Flammable metal

  • Cooking oil fires

CO2 extinguishers use a black label Dry Powder extinguishers Dry Powder extinguishers can be used on most fire types including electrical devices. Dry Powder extinguishers are also known as ABC extinguishers because they can be used on fire types A, B and C. Specialist ABC extinguishers can also be used on flammable metals such as magnesium and titanium. Powder extinguishers work to coat the fuel source and smother the fire. They will therefore stop any oxygen from getting to the fuel. Dry Powder extinguishers should not be used in confined spaces as particles that are released can be easily inhaled. Can be used on:

  • Solid fuel fires

  • Flammable liquids

  • Flammable gases

  • Flammable metal

  • Electrical fires

Not to be used on:

  • Cooking oil fires

Did you know? – According to Marsden Fire Safety A basic service on a fire extinguisher may need to be carried out every 12 months. Dry powder extinguishers use a blue label Wet Chemical Extinguishers Wet Chemical extinguishers are specifically designed to be used on fires that have cooking oils and fats as their fuel. They can also be used on solid fuel fires but it is more common to use water or foam extinguishers for these. This type of extinguisher uses a fine mist that cools flames as well as salts that form a layer on top of cooking oils. This type of extinguisher both cools and smothers the fire. Can be used on:

  • Solid fuel fires

  • Cooking oil fires

Not to be used on:

  • Flammable liquids

  • Flammable gases

  • Flammable metal

  • Electrical fires

Wet Chemical extinguishers use a yellow label

Fire Safety Awareness Course Just £20 Study online and gain a full CPD certificate posted out to you the very next working day. LEARN MORE

About the author Eve Johnson Eve has worked at CPD from the start, she organises the course and blog production, as well as supporting students with any problems they may have and helping them choose the correct courses. Eve is also studying for her Business Administration Level 3 qualification. Outside of work Eve likes to buy anything with flamingos on it, catching up with friends, spending time with her family and occasionally going to the gym!